www.rovingnetworks.com Version 1.0r 9/21/2012 80
RN-WIFLYCR-UM
Using the Built-In Sensor Power
The modules contain an on-board sensor power pin, which is controlled by the set q sensor <mask> command. <mask> is
a bit mask value that determines which sensor pins to sample when sending data using the UDP broadcast packet or the
HTTP auto-sample function. See “set q sensor <mask>” on page 19 for more details.
NOTE: In versions of firmware prior to 2.23, this command is named set option sensor.
Firmware versions 2.23 and higher support the set q power <value> command. This command sets an 8-bit register with
two 4 bit nibbles that automatically turns on the sensor power. See “set q power <value>” on page 20 for more details on
using this command.