Roving Networks RN-370 Instrukcja Użytkownika Strona 59

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 70
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 58
59
Wireless Products Division
CONFIDENTIAL
Lab 4: Auto-Posting
Sensor Data
In HTTP Client Mode, Module Sends Request Message
GET /server.php?value=0F3000001111222233334444555566667777¥n¥n
Request message includes comm remote string & sensor readings
Configure HTTP Client Mode & Request Message
Go into command mode
Associate the module with AP
set ip proto 18 // Enable HTTP & TCP protocols
set ip host 0 // Set IP address if known
set dns name www.rovingnetworks.com // Set DNS name if not
set ip remote 80 // Standard web server port
set comm remote GET$/server3.php?value= // $ is replaced by space character
set q sensor 0xff // Sample all sensors inputs
set option format 7 // Send header & sample sensor data
save & reboot
Enter command mode
open
Format
2 Bytes
GPIO
Chan
0
Chan 1 Chan 2 Chan 3 Chan 4 Chan 5 Chan 6 Chan 7
0F30 0000 1111 2222 3333 4444 5555 6666 7777